Nr | Parameter2) | Description | Comments |
1 | Radiocommunication service | - | - |
2 | Application | Euroloop | Wake-up of Euroloop transmitter by means of the train onboard equipment (OBE) transmitting on 27095 kHz. (Refer to RIR1002-02) |
3 | Frequency band | 7300 - 23000 kHz | Euroloop transmit centre frequency = 13547 kHz |
4 | Channelling | - | - |
5 | Modulation / Occupied bandwidth | BPSK, DSSS | - |
6 | Direction / Separation | - | - |
7 | Transmit power / Power density | Max. - 7 dBuA/m at 10 m | The transmitted magnetic field strength shall not exceed -7 dBuA/m at 10 m distance within the frequency band 11,1 MHz to 16,0 MHz measured in a bandwidth of 10 kHz spatially averaged over any 200 m length of the loop. Refer to EN 302 609, clause 4.2.4 for the Euroloop transmitter mask. |
8 | Channel access and occupation rules | The Euroloop shall transmit only in presence of trains, equipped with Euroloop system, on the track. | - |
9 | Authorisation regime | Switzerland: License exempt. Liechtenstein: General authorisation. | Operation on NIB / NPB. (Non interference basis / non protection basis). |
10 | Additional essential requirements | - | - |
11 | Frequency planning assumptions | EN 302 609 | ECC Report 98 |
12 | Planned changes | - | - |
13 | Reference | EN 302 609 /-/ ERC/REC 70-03, Annex 4. | Effective use of spectrum / ECC Decisions / ECC Recommendations. |
14 | Notification number | 2009/9507/CH G/TBT/N/CHE/118 | - |
15 | Remarks | EN 301 489-3 | - |
Normative part: 1 to 11
Informative part: Nr 12 to 15
1) RIR for similar and/or other applications are available under: https://www.bakom.admin.ch/bakom/en/home/frequenzen-antennen/nationaler-frequenzzuweisungsplan/schnittstellen-anforderungen.html
2) For explanations and legal status, please refer to basis document 784.101.21 / RIR0000
© OFCOM (Swiss Federal Office of Communications)