Switzerland and the Principality of Liechtenstein
Radio Interface Regulation

784.101.21 / RIR10091)
Radio microphones and ALD

RIR1009-20
Radio microphones
1350 - 1400 MHz
20mW e.i.r.p. / 50mW e.i.r.p. body worn or SSP, indoor only
Edition 1.0 / 01.01.2020

Nr Parameter2)DescriptionComments
1Radiocommunication service--
2ApplicationRadio microphonesindoor only
3Frequency band1350 - 1400 MHz-
4Channelling--
5Modulation / Occupied bandwidth--
6Direction / Separation--
7Transmit power / Power densityMax. 20mW e.i.r.p. /
Max. 50mW e.i.r.p. for body worn equipment or equipment with Spectrum Scanning Procedure (SSP).
-
8Channel access and occupation rules--
9Authorisation regimeSwitzerland: License exempt.
Liechtenstein: General authorisation.
Operation on NIB / NPB. (Non interference basis / non protection basis).
10Additional essential requirements--
11Frequency planning assumptionsEN 300 422-1 or EN 300 422-2 or EN 300 422-3.-
12Planned changes--
13ReferenceEN 300 422-1 or EN 300 422-2 or EN 300 422-3 /-/ ERC/REC 70-03, Annex 10.Effective use of spectrum / ECC Decisions / ECC Recommendations.
14Notification numberG/TBT/N/CHE/239
2019/9507/CH
-
15RemarksEN 300 422, ECC Report 245-

Normative part: 1 to 11
Informative part: Nr 12 to 15

1) RIR for similar and/or other applications are available under: https://www.bakom.admin.ch/bakom/en/home/frequenzen-antennen/nationaler-frequenzzuweisungsplan/schnittstellen-anforderungen.html
2) For explanations and legal status, please refer to basis document 784.101.21 / RIR0000