Switzerland and the Principality of Liechtenstein
Radio Interface Regulation

784.101.21 / RIR10051)
Inductive applications

RIR1005-09
Inductive applications
148.5 - 5000 kHz
-15 dBuA/m
Edition 5.1 / 01.04.2019

Nr Parameter2)DescriptionComments
1Radiocommunication service--
2ApplicationInductive applicationsApplication examples: devices for car immobilisation, animal identification, alarm systems, cable detection, waste management, personal identification, wireless voice links, access control, proximity sensors, anti-theft systems, including RF anti-theft induction systems, data transfer to handheld devices, automatic article identification, wireless control systems and automatic road tolling.
3Frequency band148.5 - 5000 kHz-
4Channelling--
5Modulation / Occupied bandwidth--
6Direction / Separation--
7Transmit power / Power densityMax. -15 dBuA/m at 10mThe maximum field strength is specified in a bandwidth of 10 kHz.
The maximum allowed field strength is -5 dBuA/m at 10m for systems operating at bandwidths larger than 10 kHz whilst keeping the density limit of -15 dBuA/m at 10m in a bandwidth of 10 kHz.
In specific bands mentioned in other radio interface regulations, higher field strengths limits and additional usage restrictions apply.
8Channel access and occupation rules--
9Authorisation regimeSwitzerland: License exempt.
Liechtenstein: General authorisation.
Operation on NIB / NPB. (Non interference basis / non protection basis).
10Additional essential requirements--
11Frequency planning assumptionsEN 300 330-
12Planned changes--
13ReferenceEN 300 330, EN 302 536 /-/ ERC/REC 70-03, Annex 9.Effective use of spectrum / ECC Decisions / ECC Recommendations.
14Notification numberG/TBT/N/CHE/153
2012/9504/CH
-
15RemarksEN 301 489-3-

Normative part: 1 to 11
Informative part: Nr 12 to 15

1) RIR for similar and/or other applications are available under: https://www.bakom.admin.ch/bakom/en/home/frequenzen-antennen/nationaler-frequenzzuweisungsplan/schnittstellen-anforderungen.html
2) For explanations and legal status, please refer to basis document 784.101.21 / RIR0000