Nr | Parameter2) | Description | Comments |
1 | Radiocommunication service | - | - |
2 | Application | NMR | For enclosed Nuclear Magnetic Resonance (NMR) applications. |
3 | Frequency band | A: 100 - 148000 Hz B: 148 - 5000 kHz C: 5 - 30 MHz D: 30 - 130 MHz | - |
4 | Channelling | - | - |
5 | Modulation / Occupied bandwidth | - | - |
6 | Direction / Separation | - | - |
7 | Transmit power / Power density | Limits for max. H-field strength: A: 100 - 148000 Hz: 46 dBµA/m at 10 m distance at 100 Hz outside the NMR device, Magnetic field strength descending 10dB/decade above 100 Hz. B: 148 - 5000 kHz: -15 dBµA/m at 10 m distance outside the NMR device. C: 5 - 30 MHz: -5 dBµA/m at 10m distance outside the NMR device. D: 30 - 130 MHz: -36 dBm e.r.p. outside the NMR device. | - |
8 | Channel access and occupation rules | - | - |
9 | Authorisation regime | Switzerland: License exempt. Liechtenstein: General authorisation. | Operation on NIB / NPB. (Non interference basis / non protection basis). |
10 | Additional essential requirements | - | - |
11 | Frequency planning assumptions | EN 303 658 (in development). | - |
12 | Planned changes | - | - |
13 | Reference | EN 303 658 /-/ ERC/REC 70-03, Annex 6. | Effective use of spectrum / ECC Decisions / ECC Recommendations. |
14 | Notification number | G/TBT/N/CHE/274 2022/9504/CH | - |
15 | Remarks | TR 103 517 | - |
Normative part: 1 to 11
Informative part: Nr 12 to 15
1) RIR for similar and/or other applications are available under: https://www.bakom.admin.ch/bakom/en/home/frequenzen-antennen/nationaler-frequenzzuweisungsplan/schnittstellen-anforderungen.html
2) For explanations and legal status, please refer to basis document 784.101.21 / RIR0000